Sample Record

DIME Sample ID 2016-01-25-6

Project Information

Project IdentifiersProject ID: 208714
DEA: 08043514
EFIS: 0800000010
DIST-CO-RTE-PM08-SBD-58-R22.2/R31.1
Award Date12/30/2014
Closeout Date08/29/2018
Work DescriptionREALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY
Location DescriptionHINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD.
QA Service Level1 (Verified on 03/22/2013)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date01/25/2016 Sample Unique Key6
Date that the sample was received by the laboratory/organization performing the testing01/27/2016 Sample typeDepartment Acceptance
A brief description of the sampleImported Borrow The quantity of what the sample constitutes2 Bags
From where was the sample collectedJob Site First name of sampler or witnessed byRene
Last name of sampler or witnessed byUnknown Title of samplerField Technician
Telephone number of samplerUnknown Laboratory sample identification6024B
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameRobertsons Barstow
Transportation Laboratory (TL) NumberC 974878 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedSR 58 Sta 1475 00 East of Dixie Road
Where the material sample would have been placed if not sampledUnknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-01-25-6-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesMd Shahjahan, CT D08 - Fontana Southern Regional Laboratory05/02/2016
No
2016-01-25-6-2CTM 217-June 2011: Method of Test for Sand EquivalentSatish Jain, CT D08 - Fontana Southern Regional Laboratory02/08/2016
No
2016-01-25-6-3CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerVincent Onoh, CT D08 - Fontana Southern Regional Laboratory02/29/2016
No
2016-01-25-6-4CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the StabilometerMd Shahjahan, CT D08 - Fontana Southern Regional Laboratory02/01/2016
No

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-01-25-6-1 CTM 202-November 2011
DIME Test ID: 2016-01-25-6-2 CTM 217-June 2011
DIME Test ID: 2016-01-25-6-3 CTM 301-March 2000
DIME Test ID: 2016-01-25-6-4 CTM 301-March 2000