Sample Record

Owner Lab

  • CT HQ - Sacramento Aggregate Testing Laboratory

DIME Sample ID 2024-02-26-33

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/26/2024 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing02/27/2024 Sample typeAggregate Prequalification Program
A brief description of the sampleWashed Concrete Sand The quantity of what the sample constitutes100 lbs
From where was the sample collectedManufacturer First name of sampler or witnessed byRon
Last name of sampler or witnessed byNovak Title of samplerQuality Control Representative
Telephone number of sampler9253035021 Laboratory sample identification
Linked DIME Sample ID2024-02-26-16 The fabricator/manufacturer/facility nameCEMEX Eliot Aggregates Quarry
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0009
The fabricator's/manufacturer's product name for the sampleWashed Concrete Sand The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-02-26-33-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesAristeo Flores, CT HQ - Sacramento Aggregate Testing Laboratory03/14/202404/11/2024
Yes
04/11/2024Public - Test Data Visible
2024-02-26-33-2CTM 213-December 2012: Method of Test for Organic Impurities in Concrete SandAristeo Flores, CT HQ - Sacramento Aggregate Testing Laboratory03/14/202404/11/2024
Yes
04/11/2024Public - Test Data Visible
2024-02-26-33-3CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium SulfateRyan Kester, CT HQ - Sacramento Aggregate Testing Laboratory04/02/202404/11/2024
Yes
04/11/2024Public - Test Data Visible
2024-02-26-33-4CTM 217-June 2011: Method of Test for Sand EquivalentAristeo Flores, CT HQ - Sacramento Aggregate Testing Laboratory03/14/202404/11/2024
Yes
04/11/2024Public - Test Data Visible
2024-02-26-33-5CTM 229-June 2011: Method of Test for Durability IndexAristeo Flores, CT HQ - Sacramento Aggregate Testing Laboratory03/15/202404/11/2024
Yes
04/11/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-02-26-33-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2024-02-26-33-2 CTM 213-December 2012 (Verified)
DIME Test ID: 2024-02-26-33-3 CTM 214-August 2010 (Verified)
DIME Test ID: 2024-02-26-33-4 CTM 217-June 2011 (Verified)
DIME Test ID: 2024-02-26-33-5 CTM 229-June 2011 (Verified)