Sample Record

DIME Sample ID 2024-01-11-49

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215220
DEA: 07210624
EFIS: 0719000068
DIST-CO-RTE-PM07-LA,SBD-71-1.8/R4.7&R0.0/R0.2
Award Date02/05/2021
Closeout DateNot set
Work DescriptionPLACE STRUCTURE CONCRETE RETAINING WALLS & BOX CULVERT AND PLACE JPCP.
Location DescriptionIN LOS ANGELES AND SAN BERNARDINO COUNTIES IN POMONA AND CHINO HILLS FROM 0.2 MILE SOUTH OF MISSION BOULEVARD OVERCROSSING TO 0.2 MILE OF SAN BERNARDINO COUNTY LINE.
QA Service Level1 (Verified on 03/24/2021)

Owner Lab

  • Alta Vista Solutions - Whittier

Sample Information

Sample Taken Date01/11/2024 Sample Unique Key49
Date that the sample was received by the laboratory/organization performing the testing01/11/2024 Sample typeQuality Assurance
A brief description of the sampleJPCP beams The quantity of what the sample constitutes10 cubic yards
From where was the sample collectedJob Site First name of sampler or witnessed byAleksey
Last name of sampler or witnessed bySouglobov Title of sampler
Telephone number of sampler Laboratory sample identification24-0144
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB060008
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected3
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-01-11-49-1CTM 523-May 2020: Method of Test for Flexural Strength of ConcreteAleksey Souglobov, Alta Vista Solutions - Whittier02/08/202403/05/2024
Yes
03/05/2024Public - Test Data Visible
2024-01-11-49-2CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteAleksey Souglobov, Alta Vista Solutions - Whittier01/11/202403/05/2024
Yes
03/05/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-01-11-49-1 CTM 523-May 2020 (Verified)
DIME Test ID: 2024-01-11-49-2 CTM 557-June 2020 (Verified)