Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2016-06-27-10
Project Information
| Project Identifiers | Project ID: 8196 DEA: 59912684 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | |
| Location Description | |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 06/27/2016 | Sample Unique Key | 10 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/04/2016 |
| Sample type | Authorization | A brief description of the sample | HY Ten Coupler |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Richard | Last name of sampler or witnessed by | Webster |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | HY Ten Reinforcement | Transportation Laboratory (TL) Number | NA |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | HY Ten |
| Coupler Manufacturer | HY Ten | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | #5, 8, 14 | Coupler Model | HTP |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | 5, 8, 14, HTS | Rebar Heat Number(s) | 4051049, 4050513, 3055577 |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2016-06-27-10-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/01/2016 | 08/01/2016 | No | necking okay | |||
| 2016-06-27-10-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/02/2016 | 08/02/2016 | No | necking okay | |||
| 2016-06-27-10-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | 100 Cycle w/ Slip | |||
| 2016-06-27-10-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | HTP Break | |||
| 2016-06-27-10-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | HTP Break | |||
| 2016-06-27-10-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | 10K Cycle | |||
| 2016-06-27-10-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | NECKING OK | |||
| 2016-06-27-10-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | 100 Cycle | |||
| 2016-06-27-10-9 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | HTP Break | |||
| 2016-06-27-10-10 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip) | Brian, CT HQ - Sacramento Structural Materials Testing Laboratory | 08/10/2016 | 08/10/2016 | No | HTP Break |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2016-06-27-10-1 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-2 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-3 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-4 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-5 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-6 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-7 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-8 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-9 CTM 670-December 2013
DIME Test ID: 2016-06-27-10-10 CTM 670-December 2013