Sample Record

DIME Sample ID 2023-11-05-18

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout Date03/13/2025
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date11/05/2023 Sample Unique Key18
Date that the sample was received by the laboratory/organization performing the testing01/26/2024 Sample typeQuality Assurance
A brief description of the sample#5 DBL Barrel Zap Screwlok The quantity of what the sample constitutes150
From where was the sample collectedJob Site First name of sampler or witnessed byK
Last name of sampler or witnessed byAllen Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVinton BarSplice
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)80162 1041 Rebar Heat Number(s)2311955
Rebar Size 2 Coupler Unique IDSB-17-02

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-11-05-18-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/30/202401/30/2024
Yes
01/31/2024Service SplicePublic - Test Data Visible
2023-11-05-18-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/202401/31/2024
Yes
01/31/2024Service SplicePublic - Test Data Visible
2023-11-05-18-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/202401/31/2024
Yes
01/31/2024Service SplicePublic - Test Data Visible
2023-11-05-18-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/31/202401/31/2024
Yes
01/31/2024Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-11-05-18-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-11-05-18-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-11-05-18-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-11-05-18-4 CTM 670-December 2013 (Verified)