Sample Record

DIME Sample ID 2024-01-24-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 993446
DEA: 120J34U4
EFIS: 1218000034
DIST-CO-RTE-PM12-ORA-55,55-29.6,R6.4/10.3
Award Date05/27/2022
Closeout DateNot set
Work DescriptionCONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION
QA Service Level1 (Verified on 06/24/2022)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date01/24/2024 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing01/26/2024 Sample typeQuality Assurance
A brief description of the sample(4) #6 rebar hoops, 3'-6" diameter The quantity of what the sample constitutes324 hoops (3 lots)
From where was the sample collectedFabricator First name of sampler or witnessed byPreston
Last name of sampler or witnessed byBrockett Title of samplerQuality Assurance Inspector
Telephone number of sampler5627836180 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameRKR Steel Welding
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL175-009-24
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202049061
Hoop Manufacturer Lot Number(s)12 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop3'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-01-24-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/29/202401/29/2024
Yes
01/31/2024Ok NeckingPublic - Test Data Visible
2024-01-24-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/29/202401/29/2024
Yes
01/31/2024Ok NeckingPublic - Test Data Visible
2024-01-24-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/29/202401/29/2024
Yes
01/31/2024Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-01-24-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-01-24-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2024-01-24-3-3 CTM 670-December 2013 (Verified)