Sample Record

DIME Sample ID 2024-01-09-29

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994864
DEA: 050N74U4
EFIS: 0522000025
DIST-CO-RTE-PM05-SB-101-9.9/10.6
Award Date07/10/2023
Closeout DateNot set
Work DescriptionSB 101 4D North San Ysidro to Olive Mill
Location DescriptionIn Santa Barbara County in and near Santa Barbara from 0.1 mile south of San Ysidro Road Overcrossing to 0.1 north of Olive Mill Road Overcrossing
QA Service Level1 (Verified on 08/21/2023)

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

Sample Information

Sample Taken Date01/09/2024 Sample Unique Key29
Date that the sample was received by the laboratory/organization performing the testing01/09/2024 Sample typeQuality Assurance
A brief description of the sample3/4 HMA Coldfeed The quantity of what the sample constitutes0-750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byJesse
Last name of sampler or witnessed byGomez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Santa Paula
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSide to Side Discharge
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number9 Aggregate Mix Number13762

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2024-01-09-29-1AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Doug Ruff, CT D05 - Carpinteria Field Laboratory01/09/202401/19/2024
Yes
01/19/2024Public - Test Data Visible
2024-01-09-29-2AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Doug Ruff, CT D05 - Carpinteria Field Laboratory01/09/202401/19/2024
Yes
01/19/2024Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-01-09-29-1 AASHTO T176-08 (Verified)
DIME Test ID: 2024-01-09-29-2 AASHTO T27-14 (Verified)