Sample Record
Owner Lab
- CT D07 - Materials Field Laboratory, Unit 1953
DIME Sample ID 2024-01-08-41
Project Information
| Project Identifiers | Project ID: 995370 DEA: 072XG004 EFIS: 0723000145 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-2-40.3/46.1 |
| Award Date | 03/22/2023 |
| Closeout Date | 11/07/2024 |
| Work Description | Remove the mudslide and rock slide behind the catchment wall, perform rock scaling, reconstruct the slope drapery protection system, rebuild the damaged slope with geogrid and subdrains, repair/replace the washed out roadway, construct earth berms and place erosion control on the washed out slopes |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 01/22/2024) |
Sample Information
| Sample Taken Date | 01/08/2024 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2024 |
| Sample type | Department Acceptance | A brief description of the sample | 4X8 PCC cylinders |
| The quantity of what the sample constitutes | 130 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Roberto | Last name of sampler or witnessed by | Appaza |
| Title of sampler | ACI | Telephone number of sampler | |
| Laboratory sample identification | 24-001 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Cal Portland | Transportation Laboratory (TL) Number | 109313 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | None |
|---|---|---|---|
| The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | NA |
| Concrete batch plant | Cal Portland | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | truck chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2024-01-08-41-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-01-08-41-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2024-01-08-41-3 CTM 521-June 2020 (Verified)