Sample Record

DIME Sample ID 2016-07-07-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209849
DEA: 07258404
EFIS: 0712000102
DIST-CO-RTE-PM07-LA-5-18.4/36.3
Award Date01/20/2016
Closeout Date10/04/2019
Work DescriptionIN LOS ANGELES COUNTY IN LOS ANGELES AND BURBANK AT VARIOUS LOCATION FROM ROUTE 60 TO ROUTE 170 CONSTRUCT GROSS SOLID REMOVAL DEVICES
Location DescriptionIN LOS ANGELES COUNTY, AT VARIOUS LOCATIONS FROM ROUTE 5/10SEPARATION TO 0.2 MILES NORTH OFFLECTCHER DRIVE UNDERCROSSING
QA Service Level1 (Verified on 08/27/2014)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date07/07/2016 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing07/11/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byTory
Last name of sampler or witnessed byMclaurin Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameTNT Rebar Nucor
Transportation Laboratory (TL) NumberC705701 Inspector Lot Number from the Transportation Laboratory (TL) FormL6712416
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-07-07-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016necking okayPublic - Test Data Visible
2016-07-07-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016necking okayPublic - Test Data Visible
2016-07-07-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016necking okayPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-07-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-07-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-07-8-3 CTM 670-December 2013 (Verified)