Sample Record

DIME Sample ID 2016-07-08-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout Date02/12/2025
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date07/08/2016 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing07/11/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedFabricator First name of sampler or witnessed byKevin
Last name of sampler or witnessed byChurchill Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rbar
Transportation Laboratory (TL) NumberC648104 Inspector Lot Number from the Transportation Laboratory (TL) FormL0205816
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4057345
Hoop Manufacturer Lot Number(s)3 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop66 250 Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-07-08-2-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-07-08-2-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-07-08-2-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/12/201607/12/2016
Yes
07/12/2016Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-08-2-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-08-2-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-08-2-3 CTM 670-December 2013 (Verified)