Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2023-08-30-96

Project Information

Project IdentifiersProject ID: 215445
DEA: 100X7504
EFIS: 1013000009
DIST-CO-RTE-PM10-ALP-4,88,89-var
Award Date03/18/2021
Closeout Date04/22/2025
Work DescriptionREPLACE BRIDGE RAIL, BARRIER SLAB AND GUARDRAIL.
Location DescriptionALPINE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date08/30/2023 Sample Unique Key96
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/30/2023
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed byTanner Last name of sampler or witnessed byBiggs
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTahoe Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberD673A
The truck number from where the sample was collected5 The batch plant ticket number from where the sample was collected88858
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedconcrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-08-30-96-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteTanner Biggs, RMA Group - Rancho Cordova08/30/202312/28/2023
Yes
12/28/2023Public - Test Data Visible
2023-08-30-96-2ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteTanner Biggs, RMA Group - Rancho Cordova08/30/202312/28/2023
Yes
12/28/2023Public - Test Data Visible
2023-08-30-96-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova08/30/202312/28/2023
Yes
12/28/2023Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-08-30-96-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2023-08-30-96-2 ASTM C143-15a (Verified)
DIME Test ID: 2023-08-30-96-3 CTM 521-June 2020 (Verified)