Sample Record

DIME Sample ID 2023-12-19-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994327
DEA: 081G4704
EFIS: 0816000001
DIST-CO-RTE-PM08-RIV-74-3.1/53.5
Award Date04/06/2023
Closeout Date10/05/2026
Work DescriptionSTRUCTURAL CONC BR, CONC SLAB, HMA (TYPE A), ALT CRASH CUSHION SYSTEM.
Location DescriptionRIVERSIDE COUNTY NEAR LAKE ELSINORE AT MORRILL CANYON BRIDGE AND NEAR HEMET AT STRAWBERRY CREEK BRIDGE.
QA Service Level1 (Verified on 06/08/2023)

Owner Lab

  • CT D08 - Corona-Stellar Structures Construction Field Office

Sample Information

Sample Taken Date12/19/2023 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing01/03/2024 Sample typeDepartment Acceptance
A brief description of the sample#5 Lenton Form Saver Coupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byArnel
Last name of sampler or witnessed byVega Title of samplerStructure Representative
Telephone number of sampler951-906-9897 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility namenVent Lenton Form Savers
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier56-0180 Structure nameStrawberry Creek Bridge
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Steel Arizona
Coupler ManufacturernVent Lenton Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelThreaded Type (SA)
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)M0129 Rebar Heat Number(s)4134862 4135144
Rebar Size 2 Coupler Unique IDST-17-05

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-12-19-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202401/04/2024
Yes
01/04/2024Service SplicePublic - Test Data Visible
2023-12-19-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202401/04/2024
Yes
01/04/2024Service SplicePublic - Test Data Visible
2023-12-19-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory01/04/202401/04/2024
Yes
01/04/2024Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-12-19-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-12-19-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-12-19-5-3 CTM 670-December 2013 (Verified)