Sample Record

DIME Sample ID 2023-12-13-28

Project Information

Project IdentifiersProject ID: 994796
DEA: 043Y6404
EFIS: 0423000269
DIST-CO-RTE-PM04-MRN-101-24.01/24.01
Award Date05/12/2023
Closeout Date05/03/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/05/2023)

Owner Lab

  • CT SC - 3672 - Petaluma

Sample Information

Sample Taken Date12/13/2023 Sample Unique Key28
Date that the sample was received by the laboratory/organization performing the testing12/13/2023 Sample typeQuality Assurance
A brief description of the sample3 - 4x8" Concrete Cylinders The quantity of what the sample constitutes54CY Facia
From where was the sample collectedJob Site First name of sampler or witnessed byJosh
Last name of sampler or witnessed byVelono Title of samplerASR
Telephone number of sampler9166218033 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameShamrock Materials Petaluma
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameSan Antonio Blvd - Emergency Soldier Pile Wall
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSL-4700CG
The truck number from where the sample was collected2445 The batch plant ticket number from where the sample was collected050839
Concrete batch plant138 Petaluma The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledFacia for Emergency Wall
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-12-13-28-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory01/10/202401/10/2024
Yes
01/10/2024Public - Test Data Visible
2023-12-13-28-2ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma12/15/202312/18/2023
Yes
12/18/2023Public - Test Data Visible
2023-12-13-28-3ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma12/15/202312/18/2023
Yes
12/18/2023Public - Test Data Visible
2023-12-13-28-4ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma12/13/202312/18/2023
Yes
12/18/2023Public - Test Data Visible
2023-12-13-28-5THIS TEST HAS BEEN SUPERSEDED.
ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Josh Velono, CT SC - 3672 - Petaluma12/13/202312/18/2023
Yes
12/18/2023THIS TEST HAS BEEN SUPERSEDED.
Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-12-13-28-1 ASTM C39-17a (Verified)
DIME Test ID: 2023-12-13-28-2 ASTM C143-15a (Verified)
DIME Test ID: 2023-12-13-28-3 ASTM C1064-08 (Verified)
DIME Test ID: 2023-12-13-28-4 ASTM C143-10a (Verified)
DIME Test ID: 2023-12-13-28-5 ASTM C1064-08 (Verified)