Sample Record

Owner Labs

  • CT SC - 3672 - Petaluma
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2023-11-22-31

Project Information

Project IdentifiersProject ID: 994796
DEA: 043Y6404
EFIS: 0423000269
DIST-CO-RTE-PM04-MRN-101-24.01/24.01
Award DateNot set
Closeout Date05/03/2024
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/05/2023)

Sample Information

Sample Taken Date11/22/2023 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/22/2023
Sample typeQuality Assurance A brief description of the sample3 - 4x8" Concrete Cylinders
The quantity of what the sample constitutes18CY 60MC Rail From where was the sample collectedJob Site
First name of sampler or witnessed byJosh Last name of sampler or witnessed byVelono
Title of samplerASR Telephone number of sampler9166218033
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameShamrock Materials Petaluma Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSan Antonio Blvd - Emergency Soldier Pile Wall

Material Information

Material TypeConcrete The concrete mix design numberSL-4700CG
The truck number from where the sample was collected5237 The batch plant ticket number from where the sample was collected493314
Concrete batch plant138 Petaluma The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampled60MC Rail
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-11-22-31-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory12/20/2023SA
Yes
12/20/2023
2023-11-22-31-2ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma11/23/2023 Philip Latasa
Yes
12/09/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-11-22-31-1 ASTM C39-17a (Verified)
DIME Test ID: 2023-11-22-31-2 ASTM C1064-08 (Verified)