Sample Record

DIME Sample ID 2023-10-07-40

Project Information

Project IdentifiersProject ID: 994803
DEA: 043J0704
EFIS: 0415000077
DIST-CO-RTE-PM04-CC-80-10.1/13.5
Award Date03/10/2023
Closeout Date10/06/2025
Work DescriptionRemove PCC and AC, place PCP and AC Resurfacing.
Location DescriptionConstruction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
QA Service Level1 (Verified on 05/10/2023)

Owner Lab

  • CT D04 - Richmond Field Laboratory

Sample Information

Sample Taken Date10/07/2023 Sample Unique Key40
Date that the sample was received by the laboratory/organization performing the testing10/10/2023 Sample typeQuality Assurance
A brief description of the sample1INCH x No.4 PCC The quantity of what the sample constitutesN/A
From where was the sample collectedSource First name of sampler or witnessed byIGNACIO
Last name of sampler or witnessed byARECHIGA Title of sampler
Telephone number of sampler5102077252 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVanguard Mobile Hercules Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)None
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSampled from Stockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberHE4x4BM Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-10-07-40-4CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesIGNACIO ARECHIGA, CT D04 - Richmond Field Laboratory10/10/202312/05/2023
Yes
12/05/2023Coarse and fines PASSED Vanguard Mobile Hercules Plant Public - Test Data Visible
2023-10-07-40-5CTM 217-June 2011: Method of Test for Sand EquivalentIGNACIO ARECHIGA, CT D04 - Richmond Field Laboratory10/10/202312/05/2023
Yes
12/05/2023PASSED Public - Test Data Visible
2023-10-07-40-6CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)IGNACIO ARECHIGA, CT D04 - Richmond Field Laboratory10/10/202312/05/2023
Yes
12/05/2023PASSED Vanguard Mobile Hercules Plant Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-07-40-4 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-10-07-40-5 CTM 217-June 2011 (Verified)
DIME Test ID: 2023-10-07-40-6 CTM 227-December 2014 (Verified)