Sample Record

DIME Sample ID 2023-10-28-25

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout Date06/09/2025
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Owner Lab

  • CT D08 - Fontana Field Testing Laboratory

Sample Information

Sample Taken Date10/28/2023 Sample Unique Key25
Date that the sample was received by the laboratory/organization performing the testing11/01/2023 Sample typeDepartment Acceptance
A brief description of the sampleRapid Set Concrete beams The quantity of what the sample constitutes15 Beams
From where was the sample collectedJob Site First name of sampler or witnessed byDennis
Last name of sampler or witnessed byRodriguez Title of sampler
Telephone number of sampler Laboratory sample identificationR11A1,R11A2,R11A3,R11B1,R11B2,R11B3,R11C1,R11C2,R11C3,R11D1,R11D2,R11D3,R11E1,R11E2,R11E3
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertson's Ready Mix - Fontana
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSM446B2R
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected8082561
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of concrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-10-28-25-1CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023Set APublic - Test Data Visible
2023-10-28-25-2CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023Set APublic - Test Data Visible
2023-10-28-25-3CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023CC not included. Set APublic - Test Data Visible
2023-10-28-25-4CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength ConcreteR. Jarquin / M. Haque, CT D08 - Fontana Field Testing Laboratory11/08/202311/27/2023
Yes
11/27/2023Set APublic - Test Data Visible
2023-10-28-25-5CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023Set BPublic - Test Data Visible
2023-10-28-25-6CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023Set BPublic - Test Data Visible
2023-10-28-25-7CTM 518-June 2010: Method of Test for Unit Weight of Fresh ConcreteDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/28/202311/27/2023
Yes
11/27/2023CC not included. Set BPublic - Test Data Visible
2023-10-28-25-8CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength ConcreteR. Jarquin / M. Haque, CT D08 - Fontana Field Testing Laboratory11/08/202311/27/2023
Yes
11/27/2023Set BPublic - Test Data Visible
2023-10-28-25-9CTM 533-June 2010: Method of Test for Ball Penetration in Fresh Portland Cement ConcreteDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/29/202311/27/2023
Yes
11/27/2023Set CPublic - Test Data Visible
2023-10-28-25-10CTM 504-June 2010: Method of Test for Determining Air Content of Freshly Mixed Concrete by the Pressure MethodDennis Rodriguez, CT D08 - Fontana Field Testing Laboratory10/29/202311/27/2023
Yes
11/27/2023Set CPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-28-25-1 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-2 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-3 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-4 CTM 524-March 2013 (Verified)
DIME Test ID: 2023-10-28-25-5 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-6 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-7 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-8 CTM 524-March 2013 (Verified)
DIME Test ID: 2023-10-28-25-9 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-10 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-11 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-12 CTM 524-March 2013 (Verified)
DIME Test ID: 2023-10-28-25-13 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-14 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-15 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-16 CTM 524-March 2013 (Verified)
DIME Test ID: 2023-10-28-25-17 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-18 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-19 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-10-28-25-20 CTM 524-March 2013 (Verified)