Sample Record

Owner Labs

  • CT SC - 3672 - Petaluma
  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2023-11-11-17

Project Information

Project IdentifiersProject ID: 993333
DEA: 04264724
EFIS: 0419000068
DIST-CO-RTE-PM04-MRN-101-R20.8/27.1
Award Date04/26/2022
Closeout DateNot set
Work DescriptionCIP BRIDGES, CONSTRUCT ROADWAY, RETAINING WALLS AND MODIFY ELECTRICAL.
Location DescriptionMARIN COUNTY IN AND NEAR NOVATO FROM 0.1 MILE SOUTH OF FRANKLIN AVENUE OVERHEAD TO 0.5 MILE SOUTH OF SAN ANTONIO CREEK BRIDGE
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date11/11/2023 Sample Unique Key17
Date that the sample was received by the laboratory/organization performing the testing11/12/2023 Sample typeQuality Assurance
A brief description of the sample12 4x8 concrete cylinders The quantity of what the sample constitutes21CY
From where was the sample collectedJob Site First name of sampler or witnessed byJosh
Last name of sampler or witnessed byVelono Title of samplerASR
Telephone number of sampler916-621-8033 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameShamrock Materials
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameRW8 footing wall 8322 to 8418
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberH7511503
The truck number from where the sample was collected2435 The batch plant ticket number from where the sample was collected481677
Concrete batch plant138 Petaluma The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCHUTE FROM TRUCK Where the material sample would have been placed if not sampledRW8 footing wall 8322 to 8418
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-11-11-17-5ASTM C143-15a: Standard Test Method for Slump of Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma11/11/202311/15/2023
Yes
11/15/2023Public - Test Data Visible
2023-11-11-17-6ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteJosh Velono, CT SC - 3672 - Petaluma11/11/202311/15/2023
Yes
11/15/2023Public - Test Data Visible
2023-11-11-17-7ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory11/20/202311/20/2023
Yes
11/20/2023Public - Test Data Visible
2023-11-11-17-8ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory11/27/202311/27/2023
Yes
11/27/2023Public - Test Data Visible
2023-11-11-17-9ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory12/04/202312/04/2023
Yes
12/04/2023Public - Test Data Visible
2023-11-11-17-10ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSA, CT HQ - Sacramento Concrete Testing Laboratory12/11/202312/11/2023
Yes
12/11/2023Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-11-11-17-5 ASTM C143-15a (Verified)
DIME Test ID: 2023-11-11-17-6 ASTM C1064-08 (Verified)
DIME Test ID: 2023-11-11-17-7 ASTM C39-17a (Verified)
DIME Test ID: 2023-11-11-17-8 ASTM C39-17a (Verified)
DIME Test ID: 2023-11-11-17-9 ASTM C39-17a (Verified)