Sample Record

DIME Sample ID 2016-05-31-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210570
DEA: 100Y90U4
EFIS: 1015000055
DIST-CO-RTE-PM10-SJ-99,15,163-18.4/23.0
Award Date12/04/2015
Closeout Date04/11/2017
Work DescriptionPLACE JPCP (RSC), COLD PLANE AC PAVEMENT, AND INSTALL RAMP METERING.
Location DescriptionSAN JOAQUIN COUNTY IN STOCKTON FROM 0.1 MILE SOUTH OF MARSH STREET PEDESTRIAN OVERCROSSING TO 0.1 MILE NORTH OF HAMMER LANE OVERCROSSING
QA Service Level1 (Verified on 09/23/2015)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/31/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing06/01/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byEd
Last name of sampler or witnessed byFleming Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameMission City Rebar
Transportation Laboratory (TL) NumberC741293 Inspector Lot Number from the Transportation Laboratory (TL) FormB1025316
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)SE15102567
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerMission City Rebar
Welding CompanyMission City Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-31-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/201606/03/2016
Yes
06/07/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-31-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/201606/03/2016
Yes
06/07/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-31-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/201606/03/2016
Yes
06/07/2016Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-31-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-31-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-31-5-3 CTM 670-December 2013 (Verified)