Sample Record

DIME Sample ID 2016-05-26-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout Date02/12/2025
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/26/2016 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing05/27/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes12
From where was the sample collectedSource First name of sampler or witnessed byWilliam
Last name of sampler or witnessed byclifford Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Rbar
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4054955
Hoop Manufacturer Lot Number(s)2 3 4 Material Standard CodeASTM A706
Material Grade60 Rebar Size8
Diameter of Hoop6'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-26-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-8CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible
2016-05-26-5-9CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/201606/01/2016
Yes
06/01/2016Bar Broke; OK NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-26-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-5-9 CTM 670-December 2013 (Verified)