Sample Record

DIME Sample ID 2016-05-26-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211049
DEA: 100Y1004
EFIS: 1013000268
DIST-CO-RTE-PM10-STA-99-R11.7/R15.0
Award Date02/22/2016
Closeout Date04/11/2017
Work DescriptionINSTALL DOUBLE LUMINAIRE.
Location DescriptionIN STANISLAUS COUNTY IN AND NEARCERES FROM NORTH STREET UNDERCROSSING TO TUOLUMNE RIVER BRIDGE
QA Service Level1 (Verified on 03/24/2016)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/26/2016 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing05/27/2016 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes8
From where was the sample collectedJob Site First name of sampler or witnessed byGreg
Last name of sampler or witnessed byThompson Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Salinas
Transportation Laboratory (TL) NumberC740269 Inspector Lot Number from the Transportation Laboratory (TL) FormB905216
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)582535
Hoop Manufacturer Lot Number(s)H08 H09 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop1'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-26-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible
2016-05-26-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible
2016-05-26-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible
2016-05-26-3-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible
2016-05-26-3-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible
2016-05-26-3-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory05/31/201605/31/2016
Yes
06/02/2016necking okayPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-26-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-3-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-3-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-3-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-3-6 CTM 670-December 2013 (Verified)