Sample Record
Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2016-05-20-6
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 209732 DEA: 072881U4 EFIS: 0714000085 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-210-R16.1/R25.8 |
| Award Date | 02/06/2015 |
| Closeout Date | 02/18/2020 |
| Work Description | CONSTRUCT CONCRETE PAVEMENT, PRECAST CONCRETE PANELS, AND SLABS. |
| Location Description | LOS ANGELES COUNTY IN LA CANADA FLINTRIDGE, GLENDALE AND PASADENA FROM DUNSMORE AVENUE UNDERCROSSING TO NORTH LOS ROBLES AVENUE OVERCROSSING |
| QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
| Sample Taken Date | 05/20/2016 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/24/2016 |
| Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | TNT Rebar | Transportation Laboratory (TL) Number | C970302 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L0804616 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 043916 |
| Hoop Manufacturer Lot Number(s) | 9 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 4 |
| Diameter of Hoop | 2'-2" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | TNT Rebar | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2016-05-20-6-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-20-6-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-20-6-3 CTM 670-December 2013 (Verified)