Sample Record

DIME Sample ID 2016-05-19-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210737
DEA: 073X7114
EFIS: 0715000132
DIST-CO-RTE-PM07-LA-60,126-R7.4/R8.1
Award Date11/16/2015
Closeout Date06/16/2021
Work DescriptionREALIGN RAMPS, WIDEN BRIDGE, AND REPLACE RAMPS PAVEMENT.
Location DescriptionIN LA COUNTY, IN CITY OF MONTEBELLOAT PARAMOUNT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 12/11/2015)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date05/19/2016 Sample Unique Key4
Date that the sample was received by the laboratory/organization performing the testing05/20/2016 Sample typeQuality Control
A brief description of the sample6X12 The quantity of what the sample constitutes2
From where was the sample collectedJob Site First name of sampler or witnessed byJOHN
Last name of sampler or witnessed byLEE Title of samplerSR
Telephone number of samplerUnknown Laboratory sample identification929-35
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNATIONAL READY MIX
Transportation Laboratory (TL) Number111835 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierROUTE 60 Structure name60 PARAMOUNT WB ON RAMP
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS72500
The truck number from where the sample was collected476 The batch plant ticket number from where the sample was collected11835
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTRUCK Where the material sample would have been placed if not sampledUnknown
From Lot No.Unknown Bag Lot No.Unknown

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-19-4-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory06/16/2016
Yes
06/16/2016Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-19-4-1 ASTM C39-17a (Verified)