Sample Record

DIME Sample ID 2016-05-06-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209576
DEA: 11263304
EFIS: 1100000743
DIST-CO-RTE-PM11-IMP-8-R38.8/R39.1
Award Date07/30/2014
Closeout Date04/09/2018
Work DescriptionBRIDGE REPLACEMENT AND MODIFY INTERCHANGE.
Location DescriptionIMPERIAL COUNTY IN EL CENTRO FROM 0.2 MILE WEST TO 0.1 MILE EAST OF DOGWOOD ROAD OVERCROSSING
QA Service Level1 (Verified on 11/11/2014)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date05/06/2016 Sample Unique Key7
Date that the sample was received by the laboratory/organization performing the testing05/20/2016 Sample typeQuality Assurance
A brief description of the sampleLenton Couplers The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byMichael
Last name of sampler or witnessed byNguyen Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCMC Erico
Transportation Laboratory (TL) NumberUnknown Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or FabricatorUnknown
Rebar Size#11 Coupler ModelLenton
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)L8613 Rebar Heat Number(s)4053814
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2016-05-06-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/23/201605/23/2016
Yes
05/23/2016Service SplicePublic - Test Data Visible
2016-05-06-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/23/201605/23/2016
Yes
05/23/2016Service SplicePublic - Test Data Visible
2016-05-06-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory05/23/201605/23/2016
Yes
05/23/2016Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-06-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-06-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-06-7-3 CTM 670-December 2013 (Verified)