Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2016-01-06-4
Project Information
| Project Identifiers | Project ID: 209917 DEA: 072656U4 EFIS: 0714000100 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-138-69.9/75.0 |
| Award Date | 02/25/2015 |
| Closeout Date | 06/16/2021 |
| Work Description | WIDEN ROADWAY AND COLD PLANE ASPHALT PAVEMENT AND PLACE HMA. |
| Location Description | LOS ANGELES COUNTY FROM 0.5 MILE EAST OF ROUTE 18/138 JUNCTION TO SAN BERNARDINO COUNTY LINE |
| QA Service Level | 1 (Verified on 03/19/2015) |
Sample Information
| Sample Taken Date | 01/06/2016 | Sample Unique Key | 4 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/06/2016 |
| Sample type | Department Acceptance | A brief description of the sample | Class 3 Aggregate Base |
| The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Eric | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Tester | Telephone number of sampler | Unknown |
| Laboratory sample identification | 6000B | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | C 936601 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | Sta 41 00 Sta 79 00 and Sta 80 50 |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2016-01-06-4-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Nader Rashidi, CT D08 - Fontana Southern Regional Laboratory | 01/20/2016 | No | |||||
| 2016-01-06-4-2 | CTM 217-June 2011: Method of Test for Sand Equivalent | MD Shahjahan, CT D08 - Fontana Southern Regional Laboratory | 01/21/2016 | No | |||||
| 2016-01-06-4-3 | CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer | Vincent Onoh, CT D08 - Fontana Southern Regional Laboratory | 01/22/2016 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2016-01-06-4-1 CTM 202-November 2011
DIME Test ID: 2016-01-06-4-2 CTM 217-June 2011
DIME Test ID: 2016-01-06-4-3 CTM 301-March 2000