Sample Record

Owner Lab

  • CT D06 - Bakersfield Field Laboratory

DIME Sample ID 2023-10-13-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995173
MINOR: 06A2922
DIST-CO-RTE-PM06-KER-178-R40.6
Award DateNot set
Closeout DateNot set
Work DescriptionCold plane AC pavement and place HMA (Type A)
Location DescriptionConstruction in Kern County at Bodfish Maintenance Station
QA Service Level1 (Verified on 10/26/2023)

Sample Information

Sample Taken Date10/13/2023 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/13/2023
Sample typeDepartment Acceptance A brief description of the sampleHMA type A
The quantity of what the sample constitutes750 Tons From where was the sample collectedSource
First name of sampler or witnessed byPaul Last name of sampler or witnessed byKlinker
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91150114
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Plant Cold Feed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number2 Aggregate Mix Number1468

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-10-13-3-1AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by WashingJames Watson, CT D06 - Bakersfield Field Laboratory10/13/2023Kulwinder Rai
Yes
10/13/2023L1SL2
2023-10-13-3-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)James Watson, CT D06 - Bakersfield Field Laboratory10/13/2023Kulwinder Rai
Yes
10/13/2023L1SL2
2023-10-13-3-3AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)James Watson, CT D06 - Bakersfield Field Laboratory10/13/2023Kulwinder Rai
Yes
10/13/2023L1SL2

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-10-13-3-1 AASHTO T11-5 (Verified)
DIME Test ID: 2023-10-13-3-2 AASHTO T176-08 (Verified)
File NameExtensionDate UploadedTest IDActions
06-06A2922_37005_231013_L1SL2_HMAGradation_T11T27T176pdf10/13/20232023-10-13-3-2   Info

DIME Test ID: 2023-10-13-3-3 AASHTO T27-14 (Verified)
File NameExtensionDate UploadedTest IDActions
06-06A2922_37005_231013_L1SL2_HMAGradation_T11T27T176pdf10/13/20232023-10-13-3-3   Info