Sample Record

DIME Sample ID 2023-09-21-80

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994785
DEA: 023H32U4
EFIS: 0221000164
DIST-CO-RTE-PM02-SIS-I5-2.5/R15.9
Award Date04/28/2023
Closeout DateNot set
Work DescriptionRoadway rehabilitation and bridge improvements along I5 in Mount Shasta
Location DescriptionSIS I5 2.5/R15.9
QA Service Level1 (Verified on 05/03/2023)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date09/21/2023 Sample Unique Key80
Date that the sample was received by the laboratory/organization performing the testing10/10/2023 Sample typeQuality Assurance
A brief description of the sample Dayton Superior coupler The quantity of what the sample constitutes4
From where was the sample collectedManufacturer First name of sampler or witnessed byMike
Last name of sampler or witnessed bySears Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameComblin Steel
Transportation Laboratory (TL) Numberc778604 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerDayton Superiour
Coupler ManufacturerBarlock Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000003595 Rebar Heat Number(s)2310734
Rebar Size 2 Coupler Unique IDSL-17-01

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-09-21-80-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/202310/10/2023
Yes
10/12/2023Service SplicePublic - Test Data Visible
2023-09-21-80-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/202310/10/2023
Yes
10/12/2023Service SplicePublic - Test Data Visible
2023-09-21-80-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory10/10/202310/10/2023
Yes
10/12/2023Service SplicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-09-21-80-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2023-09-21-80-2 CTM 670-December 2013 (Verified)