Sample Record

Owner Lab

  • CT D04 - Richmond Field Laboratory

DIME Sample ID 2023-09-03-12

Project Information

Project IdentifiersProject ID: 994803
DEA: 043J0704
EFIS: 0415000077
DIST-CO-RTE-PM04-CC-80-10.1/13.5
Award Date03/10/2023
Closeout DateNot set
Work DescriptionRemove PCC and AC, place PCP and AC Resurfacing.
Location DescriptionConstruction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date09/03/2023 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2023
Sample typeQuality Assurance A brief description of the samplePCC Beams
The quantity of what the sample constitutesN/A From where was the sample collectedJob Site
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of sampler Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVanguard Hercules Mobile Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberC90 Pave
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedNone
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-09-03-12-5CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength ConcreteIGNACIO ARECHIGA, CT D04 - Richmond Field Laboratory09/13/2023IGNACIO ARECHIGA
Yes
10/09/2023Beams PASSED Beam Set 7 B Vanguard Mobile Hercules Plant B

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-09-03-12-5 CTM 524-March 2013 (Verified)