Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2016-02-16-6
Project Information
| Project Identifiers | Project ID: 210929 DEA: 08465514 EFIS: 0815000117 MINOR: 08A2538 |
|---|---|
| DIST-CO-RTE-PM | 08--VAR-VAR |
| Award Date | 07/01/2015 |
| Closeout Date | 08/05/2016 |
| Work Description | Install 10 solar powered Traffic Monitoring Stations at various routes and locations in Riverside County. The work per location includes installing a 30 foot steel pole about 20 feet from edge of traveled way with an attached cabinet that house the vehicle detection equipment and installing 2 loop d |
| Location Description | ON STATE HIGHWAY IN VARIOUS CITIES, ROUTES AND POST MILES IN RIVERSIDE COUNTY |
| QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
| Sample Taken Date | 02/16/2016 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/17/2016 |
| Sample type | Annual Source Testing | A brief description of the sample | Three eighths inch rock |
| The quantity of what the sample constitutes | 4 Bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | 6070B | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Associated Ready Mix | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | SMARA 91 33 0072 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| The plant number | Unknown | A detailed description of where the material sample was collected | West Coast Indio |
| Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
| The concrete mix design number | Lot number | Not set | |
| Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
| DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Date Added | Verified? | Release Date | Test Comments | Privacy Level | Actions |
|---|---|---|---|---|---|---|---|---|---|
| 2016-02-16-6-1 | CTM 206-October 2011: Method of Test for Specific Gravity and Absorption of Coarse Aggregate | Danilo Ferrer, CT D08 - Fontana Southern Regional Laboratory | 02/23/2016 | No | |||||
| 2016-02-16-6-2 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | Danilo Ferrer, CT D08 - Fontana Southern Regional Laboratory | 02/23/2016 | No | |||||
| 2016-02-16-6-3 | CTM 211-May 2010: Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine | Danilo Ferrer, CT D08 - Fontana Southern Regional Laboratory | 02/23/2016 | No | |||||
| 2016-02-16-6-4 | CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate | Nemencio Daof, CT D08 - Fontana Southern Regional Laboratory | 03/03/2016 | No | |||||
| 2016-02-16-6-5 | CTM 227-June 2012: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness) | Satish Jain, CT D08 - Fontana Southern Regional Laboratory | 02/24/2016 | No |
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2016-02-16-6-1 CTM 206-October 2011
DIME Test ID: 2016-02-16-6-2 CTM 202-November 2011
DIME Test ID: 2016-02-16-6-3 CTM 211-May 2010
DIME Test ID: 2016-02-16-6-4 CTM 214-August 2010
DIME Test ID: 2016-02-16-6-5 CTM 227-June 2012