DIME Sample ID 2023-07-21-55

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 995048
DEA: 061E5604
EFIS: 0622000066
DIST-CO-RTE-PM06-FRE-198-21.2/22.7
Award Date01/05/2023
Closeout Date11/16/2023
Work DescriptionCold plane existing asphalt pavement and place RHMA.
Location DescriptionNot set
QA Service Level1 (Verified on 08/04/2023)

Sample Information

Sample Taken Date07/21/2023 Sample Unique Key55
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/29/2023
Sample typeDispute Resolution A brief description of the sample1/2" Aggregate
The quantity of what the sample constitutes4 Bags From where was the sample collectedSource
First name of sampler or witnessed byA. Last name of sampler or witnessed byM.
Title of sampler Telephone number of sampler
Laboratory sample identification23-JFMDISP-167 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Colinga Transportation Laboratory (TL) NumberC027842
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0005
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedHMA Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-07-21-55-1AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory08/31/2023Bang Nguyen
Yes
09/01/2023
2023-07-21-55-2AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Bulk specific gravity (SSD) of fine aggregate, Bulk specific gravity of fine aggregate, Apparent specific gravity of fine aggregate, Apparent specific gravity of supplemental fines, Absorption of fine aggregate
2023-07-21-55-3AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Bulk Specific Gravity (Oven Dry) of Coarse Aggregate-Absorption of Coarse Aggregate.
2023-07-21-55-4AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/01/2023Bang Nguyen
Yes
09/08/2023Sand equivalent (min)
2023-07-21-55-5AASHTO T210-15: Standard Method of Test for Aggregate Durability Index (Durability Index)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/05/2023Bang Nguyen
Yes
09/08/2023Durability Procedure "A" Coarse Aggregate and Procedure "B" Fine Aggregate.
2023-07-21-55-6AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Method A
2023-07-21-55-7AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Los Angeles Rattler, Loss at 100 and 500 Rev.
2023-07-21-55-8AASHTO T335-09r13: Standard Method of Test for Determining the Percentage of Fracture in Coarse Aggregate (Percent of Crushed Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Crushed particles, coarse aggregate One fractured face and Crushed particles, coarse aggregate Two fractured faces - Method 1 Crushed particles, fine aggregate (Passing No. 4 sieve and retained on No. 8 sieve) One fractured face - Method 2
2023-07-21-55-9ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)Ryan Kester, CT HQ - Sacramento Aggregate Testing Laboratory09/07/2023Bang Nguyen
Yes
09/08/2023Flat and elongated particles (% by mass at 5:1)

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-07-21-55-1 AASHTO T27-14 (Verified)
DIME Test ID: 2023-07-21-55-2 AASHTO T84-14 (Verified)
DIME Test ID: 2023-07-21-55-3 AASHTO T85-13 (Verified)
DIME Test ID: 2023-07-21-55-4 AASHTO T176-08 (Verified)
DIME Test ID: 2023-07-21-55-5 AASHTO T210-15 (Verified)
DIME Test ID: 2023-07-21-55-6 AASHTO T304-11 (Verified)
DIME Test ID: 2023-07-21-55-7 AASHTO T96-02r10 (Verified)
DIME Test ID: 2023-07-21-55-8 AASHTO T335-09r13 (Verified)
DIME Test ID: 2023-07-21-55-9 ASTM D4791-10 (Verified)