Sample Record
DIME Sample ID 2023-08-23-51
Project Information
| Project Identifiers | Project ID: 994589 DEA: 081H4914 EFIS: 0819000118 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-18-53.1/69.0 |
| Award Date | 05/16/2023 |
| Closeout Date | 08/01/2024 |
| Work Description | REPLACE AC SURF, HMA (TYPE A), AND COLD CENTRAL PLANT RECYCLING. |
| Location Description | SAN BERNARDINO COUNTY NEAR BIG BEAR LAKE FROM 0.4 MILE EAST OF PINEVIEW DRIVE TO 0.1 MILE NORTH OF RICHARD STREET AND VISALIA AVENUE |
| QA Service Level | 1 (Verified on 07/14/2023) |
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
Sample Information
| Sample Taken Date | 08/23/2023 | Sample Unique Key | 51 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/25/2023 | Sample type | Verification |
| A brief description of the sample | PSUE 3/4" HMA-A-SP R15 0.6% LAS | The quantity of what the sample constitutes | 4 Bags Of Agg., 1 Bag Rap |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Francisco |
| Last name of sampler or witnessed by | Alex | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | 0433A-23 | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Blue Diamond-Victorville | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0106 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Belt Cut ay Blue Diamond-Victorville | |
| Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | 300154 | Lot number | |
| Sublot number | Aggregate Mix Number |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-08-23-51-1 AASHTO T27-14 (Verified)
DIME Test ID: 2023-08-23-51-2 AASHTO T84-14 (Verified)
DIME Test ID: 2023-08-23-51-3 AASHTO T85-13 (Verified)
DIME Test ID: 2023-08-23-51-4 AASHTO T96-02r10 (Verified)
DIME Test ID: 2023-08-23-51-5 AASHTO T176-08 (Verified)
DIME Test ID: 2023-08-23-51-6 AASHTO T304-11 (Verified)
DIME Test ID: 2023-08-23-51-7 AASHTO T335-09r13 (Verified)
DIME Test ID: 2023-08-23-51-8 ASTM D4791-10 (Verified)
DIME Test ID: 2023-08-23-51-9 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-08-23-51-10 CTM 202-November 2011 (Verified)