Sample Record
Owner Lab
- CT D05 - Carpinteria Field Laboratory
DIME Sample ID 2023-07-21-50
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 994408 DEA: 051K03U4 EFIS: 0522000026 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-101- |
| Award Date | 10/04/2022 |
| Closeout Date | Not set |
| Work Description | !!PLEASE CC Office Engineer Barbara Riccardi on reports to RE and SR!! Construct 2 roundabouts in Montecito along US 101. |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/29/2022) |
Sample Information
| Sample Taken Date | 07/21/2023 | Sample Unique Key | 50 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2023 |
| Sample type | Quality Assurance | A brief description of the sample | PCC - CRCP |
| The quantity of what the sample constitutes | 120 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Thomas | Last name of sampler or witnessed by | Cromwell |
| Title of sampler | Telephone number of sampler | 8057465506 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CEMEX Santa Barbara | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1625995 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 30845503 | |
| Concrete batch plant | Cemex Santa Barbara | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Discharge from concrete truck into wheelbarrow | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-07-21-50-1 ASTM C1064-17 (Verified)
DIME Test ID: 2023-07-21-50-2 ASTM C231-17a (Verified)
DIME Test ID: 2023-07-21-50-3 CTM 533-June 2010 (Verified)
DIME Test ID: 2023-07-21-50-4 ASTM C78-18 (Verified)
DIME Test ID: 2023-07-21-50-5 ASTM C78-18 (Verified)