Sample Record
DIME Sample ID 2023-03-01-32
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 214663 DEA: 081F7304 EFIS: 0815000034 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-215-2.7 |
| Award Date | 03/04/2021 |
| Closeout Date | 06/03/2025 |
| Work Description | REPLACE CONCRETE BRIDGE, PLACE CONCRETE PCPS GIRDERS AND HMA. |
| Location Description | SAN BERNARDINO COUNTY IN COLTON AT WASHINGTON STREET OVERCROSSING |
| QA Service Level | 1 (Verified on 02/24/2021) |
Owner Lab
- G3 Quality, Incorporated - Cerritos
Sample Information
| Sample Taken Date | 03/01/2023 | Sample Unique Key | 32 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 03/02/2023 | Sample type | Quality Control |
| A brief description of the sample | 1in, 3/8 in, WCS | The quantity of what the sample constitutes | 1 Bag |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | Adrian |
| Last name of sampler or witnessed by | Lopez | Title of sampler | QC Field Technician |
| Telephone number of sampler | Laboratory sample identification | Mix 1610838 | |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Job site |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | 00-0000 | Structure name | |
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | Set 1 | The fabricator/manufacturer designation for the sample | |
| The plant number | A detailed description of where the material sample was collected | Belt | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | 1610838 | Lot number | 1 |
| Sublot number | 1 | Aggregate Mix Number |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-03-01-32-1 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-03-01-32-2 CTM 202-November 2011 (Verified)
DIME Test ID: 2023-03-01-32-3 CTM 217-June 2011 (Verified)
DIME Test ID: 2023-03-01-32-4 CTM 226-July 2010 (Verified)
DIME Test ID: 2023-03-01-32-5 CTM 227-December 2014 (Verified)