Sample Record
Owner Lab
- G3 Quality, Incorporated - Cerritos
DIME Sample ID 2023-02-16-87
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
Award Date | 04/23/2021 |
Closeout Date | Not set |
Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 02/16/2023 | Sample Unique Key | 87 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/17/2023 |
Sample type | Quality Control | A brief description of the sample | 4x8 concrete cylinders |
The quantity of what the sample constitutes | 7 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Al | Last name of sampler or witnessed by | Pineda |
Title of sampler | QC Field Tech | Telephone number of sampler | |
Laboratory sample identification | Set 2 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 85Q41S1P |
---|---|---|---|
The truck number from where the sample was collected | Load 13 | The batch plant ticket number from where the sample was collected | 0 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | Set 2 | |
A detailed description of where the material sample was collected | J st Bridge Stem Soffit Bent 2 | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-02-16-87-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-02-16-87-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-02-16-87-3 CTM 557-June 2020 (Verified)
DIME Test ID: 2023-02-16-87-4 CTM 518-June 2010 (Verified)
DIME Test ID: 2023-02-16-87-5 CTM 504-June 2010 (Verified)
DIME Test ID: 2023-02-16-87-6 CTM 556-January 2018 (Verified)