Sample Record
Owner Labs
- CT HQ - QASI Los Angeles Field Office
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2023-07-18-7
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 212720 DEA: 07291404 EFIS: 0712000094 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-1-55-58 |
| Award Date | 02/18/2021 |
| Closeout Date | Not set |
| Work Description | TRANCAS CREEK BRIDGE REPLACEMENT |
| Location Description | IN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027). |
| QA Service Level | 1 (Verified on 04/02/2021) |
Sample Information
| Sample Taken Date | 07/18/2023 | Sample Unique Key | 7 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/30/2023 |
| Sample type | Quality Assurance | A brief description of the sample | ASTM A706 gr 60 epoxy coated ASTM A775 |
| The quantity of what the sample constitutes | 85 bars | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Henry | Last name of sampler or witnessed by | Arredondo |
| Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 5623329603 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Rebar San Bernardino | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L166-067-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4116723 |
|---|---|---|---|
| Rebar Epoxy Batch Number(s) | A220196 | Rebar Coating Specification | ASTM A775 |
| Rebar Size (#) | 5 | Rebar Coating Color | Green |
| Rebar Manufacturer | CMC Steel AZ | Rebar Coater | CMC Rebar San Bernardino |
| Rebar Powder Manufacturer | IFS Coatings | Release Number | |
| Quality Assurance Code |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-07-18-7-1 ASTM A775-19 (Verified)
DIME Test ID: 2023-07-18-7-2 ASTM A775-07b-re14 (Verified)