Sample Record

DIME Sample ID 2023-06-14-70

Project Information

Project IdentifiersProject ID: 993664
DEA: 073311U4
EFIS: 0719000098
DIST-CO-RTE-PM07-VEN-23,101-R3.3/R3.7,0.2/40.8
Award Date08/31/2022
Closeout DateNot set
Work DescriptionCONSTRUCT GUARDRAILS AND CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS, CAMARILLO, OXNARD AND VENTURA ON ROUTE 101 FROM THE LOS ANGELES /VENTURA COUNTY LINE TO OLD PACIFIC COAST HIGHWAY AND ON ROUTE 23 FROM ROUTE 23/101 SEPARATION TO HILLCREST DRIVE
QA Service Level1 (Verified on 05/11/2022)

Owner Lab

  • CT D07 - Materials Field Laboratory, Unit 1953

Sample Information

Sample Taken Date06/14/2023 Sample Unique Key70
Date that the sample was received by the laboratory/organization performing the testing06/16/2023 Sample typeDepartment Acceptance
A brief description of the sample6X12 PCC cylinder The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byAna
Last name of sampler or witnessed byTrujillo Title of samplerAssistant Structure Representative
Telephone number of sampler Laboratory sample identification23-206
Linked DIME Sample ID The fabricator/manufacturer/facility nameAssociated Ready Mix
Transportation Laboratory (TL) Number061423 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSL590330
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected6844641
Concrete batch plantAssociated Ready Mix Oxnard The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-06-14-70-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersArnold Truong, CT D07 - Materials Field Laboratory, Unit 195306/21/202306/21/2023
Yes
06/21/2023Public - Test Data Visible
2023-06-14-70-2CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersRobert Achuela, CT D07 - Materials Field Laboratory, Unit 195306/28/202306/28/2023
Yes
06/28/2023Public - Test Data Visible
2023-06-14-70-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersArnold Truong, CT D07 - Materials Field Laboratory, Unit 195307/12/202307/12/2023
Yes
07/12/2023Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-06-14-70-1 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-06-14-70-2 CTM 521-June 2020 (Verified)
DIME Test ID: 2023-06-14-70-3 CTM 521-June 2020 (Verified)