Sample Record

DIME Sample ID 2023-06-09-13

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214135
DEA: 09213404
EFIS: 0900000030
DIST-CO-RTE-PM09-INY-395-29.9/41.8
Award Date10/22/2021
Closeout Date05/29/2026
Work DescriptionROADWAY EXCAVATION, PLACE HMA (TYPE A), AND ALTERNATIVE PIPE CULVERT.
Location DescriptionINYO COUNTY NEAR OLANCHA AND CARTAGO FROM 1.4 MILES SOUTH OF LOS ANGELES AQUEDUCT BRIDGE TO 0.2 MILE SOUTH OF ASH CREEK BRIDGE
QA Service Level1 (Verified on 05/03/2019)

Owner Lab

  • CT D09 - Bishop Field Laboratory

Sample Information

Sample Taken Date06/09/2023 Sample Unique Key13
Date that the sample was received by the laboratory/organization performing the testing06/09/2023 Sample typeQuality Assurance
A brief description of the sampleDS 1119 Headwall Footing The quantity of what the sample constitutes4x8 Cylinders Casted
From where was the sample collectedSupplier First name of sampler or witnessed byDerek
Last name of sampler or witnessed byArmon Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility name711 Materials Ridgecrest
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number718216A
The truck number from where the sample was collected84003 The batch plant ticket number from where the sample was collectedConcrete Plant
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete Trucks loads Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-06-09-13-2ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensDerek Carrington, CT D09 - Bishop Field Laboratory07/07/202307/10/2023
Yes
07/10/20233 broken @ 28 DaysPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-06-09-13-2 ASTM C39-10 (Verified)