Sample Record

DIME Sample ID 2023-05-31-34

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 994851
DEA: 034J5004
EFIS: 0323000177
DIST-CO-RTE-PM03-SAC-51-0.24/0.24
Award Date05/08/2023
Closeout Date04/01/2025
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/31/2023)

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

Sample Information

Sample Taken Date05/31/2023 Sample Unique Key34
Date that the sample was received by the laboratory/organization performing the testing05/31/2023 Sample typePer Request
A brief description of the sample4x6 Concrete Cores The quantity of what the sample constitutes3 Concrete Cores
From where was the sample collectedJob Site First name of sampler or witnessed byMike
Last name of sampler or witnessed byMullins Title of samplerMREA
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCaltrans
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameFort Sutter Viaduct
Bid ItemNot set

Material Information

Material TypeConcrete Core Detail descriptionConcrete
Structure namesFort Sutter Viaduct Type of materialConcrete

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2023-05-31-34-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSpencer Adams, CT HQ - Sacramento Concrete Testing Laboratory05/31/202306/06/2023
Yes
06/06/2023Core #1 | Length: 4.87" | Diameter: 4.09" | Correction Factor: 0.935 | Corrected Strength: 4937 psiPublic - Test Data Visible
2023-05-31-34-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSpencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/05/202306/06/2023
Yes
06/06/2023Core #2 | Length: 5.57" | Diameter: 4.08" | Correction Factor: 0.944 | Corrected Strength: 5025 psiPublic - Test Data Visible
2023-05-31-34-3ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensSpencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/05/202306/06/2023
Yes
06/06/2023Core #5 | Length: 5.62" | Diameter: 4.09" | Correction Factor: 0.945 | Corrected Strength: 4772 psiPublic - Test Data Visible
2023-05-31-34-4ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/01/202306/06/2023
Yes
06/06/2023Core #2Public - Test Data Visible
2023-05-31-34-5ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/01/202306/06/2023
Yes
06/06/2023Core #5Public - Test Data Visible
2023-05-31-34-6ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/05/202306/06/2023
Yes
06/06/2023Core #2Public - Test Data Visible
2023-05-31-34-7ASTM C469-14: Standard Test Method for Static Modulus of Elasticity and Poisson's Ratio of Concrete in Compression (Static Modulus of Elasticity)Spencer Adams, CT HQ - Sacramento Concrete Testing Laboratory06/05/202306/06/2023
Yes
06/06/2023Core #5Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-05-31-34-1 ASTM C39-17a (Verified)
DIME Test ID: 2023-05-31-34-2 ASTM C39-17a (Verified)
DIME Test ID: 2023-05-31-34-3 ASTM C39-17a (Verified)
DIME Test ID: 2023-05-31-34-4 ASTM C469-14 (Verified)
DIME Test ID: 2023-05-31-34-5 ASTM C469-14 (Verified)
DIME Test ID: 2023-05-31-34-6 ASTM C469-14 (Verified)
DIME Test ID: 2023-05-31-34-7 ASTM C469-14 (Verified)