Sample Record
DIME Sample ID 2015-09-17-9
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 209153 DEA: 043A8704 EFIS: 0400000967 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-680-22.7/24.8 |
| Award Date | 04/16/2014 |
| Closeout Date | 09/28/2016 |
| Work Description | RETROFIT BRIDGE, REPLACE BRIDGE, AND CONSTRUCT EMERGENCY ACCESS LANE. |
| Location Description | CONTRA COSTA COUNTY IN AND NEAR MARTINEZ FROM ARTHUR ROAD UNDERCROSSING TO 0.5 MILE NORTH OF MOCOCO OVERHEAD |
| QA Service Level | 1 (Verified on 02/06/2014) |
Owner Lab
- CT HQ - Sacramento Concrete Testing Laboratory
Sample Information
| Sample Taken Date | 09/17/2015 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/12/2015 | Sample type | Quality Control |
| A brief description of the sample | concrete | The quantity of what the sample constitutes | cylinders |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | E |
| Last name of sampler or witnessed by | Li | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | unknown |
| Transportation Laboratory (TL) Number | 207246 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Unknown | Structure name | Unknown |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 1580621 |
|---|---|---|---|
| The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | unknown |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | load 1 truck 5519 | Where the material sample would have been placed if not sampled | conctete barrier |
| From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2015-09-17-9-1 ASTM C39-17a (Verified)