Sample Record
Owner Lab
- CT D06 - Visalia Field Laboratory
DIME Sample ID 2023-01-06-51
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 993301 DEA: 060U2804 EFIS: 0615000293 |
---|---|
DIST-CO-RTE-PM | 06-TUL-245-1.4,4.2 |
Award Date | 01/03/2022 |
Closeout Date | Not set |
Work Description | PRECAST PRESTRESSED CONCRETE BOX GIRDER AND SLAB, BRIDGE REMOVAL. |
Location Description | TULARE COUNTY NEAR WOODLAKE AT YOKOHL CREEK BRIDGE AND AT KAWEAH RIVER BRIDGE |
QA Service Level | 1 (Verified on 10/11/2021) |
Sample Information
Sample Taken Date | 01/06/2023 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/06/2023 |
Sample type | Quality Assurance | A brief description of the sample | Type II Cement Agg 4x8 Concrete Cylinders |
The quantity of what the sample constitutes | Kaweah Bridge Column | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Bandy | Last name of sampler or witnessed by | Ahmed |
Title of sampler | Structure Representative | Telephone number of sampler | 559-284-9223 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Viking Ready Mix Visalia | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Tul 245 Kaweah Bridge Colmn , WoodLake |
Material Information
Material Type | Concrete | The concrete mix design number | ND22023 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 897510 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Cylinders Fabricated at the site | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2023-01-06-51-1 CTM 521-June 2020 (Verified)
File Name | Extension | Date Uploaded | Test ID | Actions |
---|---|---|---|---|
06-0U2804_37000_221202_SA_35D | 04/03/2023 | 2023-01-06-51-1 | Info |
DIME Test ID: 2023-01-06-51-2 CTM 521-June 2020 (Verified)
File Name | Extension | Date Uploaded | Test ID | Actions |
---|---|---|---|---|
06-0U2804_37000_221202_SA_14D | 04/03/2023 | 2023-01-06-51-2 | Info |