Sample Record

Owner Lab

  • CT D05 - Carpinteria Field Laboratory

DIME Sample ID 2023-02-14-49

Project Information

Project IdentifiersProject ID: 994087
DEA: 051G4104
EFIS: 0515000012
DIST-CO-RTE-PM05-SB-101-4.0/4.8
Award Date09/02/2022
Closeout Date08/12/2024
Work DescriptionSanta Claus Lane Bike Path - !!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
Location Description!!Charge time to 05-0N72U4 per Project Manager / Corridor Manager!!
QA Service Level1 (Verified on 07/25/2022)

Sample Information

Sample Taken Date02/14/2023 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/14/2023
Sample typeDepartment Acceptance A brief description of the sampleConcrete Sample
The quantity of what the sample constitutes15 CY From where was the sample collectedJob Site
First name of sampler or witnessed byTom Last name of sampler or witnessed byCromwell
Title of sampler Telephone number of sampler8056991626
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta Goleta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number725A1Z0P
The truck number from where the sample was collected550 The batch plant ticket number from where the sample was collected3432930
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDischarge from concrete truck into wheelbarrow. Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2023-02-14-49-1ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteTom Cromwell, CT D05 - Carpinteria Field Laboratory02/14/2023Darren LaChaine
Yes
03/16/2023
2023-02-14-49-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteTom Cromwell, CT D05 - Carpinteria Field Laboratory02/14/2023Darren LaChaine
Yes
03/16/2023

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2023-02-14-49-1 ASTM C1064-17 (Verified)
DIME Test ID: 2023-02-14-49-2 ASTM C143-20 (Verified)