Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2023-01-19-5
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 993782 DEA: 07339604 EFIS: 0717000157 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-14-R29.0/R29.5 |
| Award Date | 07/06/2022 |
| Closeout Date | 11/05/2025 |
| Work Description | CONSTRUCT SLOPE BETTERMENT. |
| Location Description | LOS ANGELES COUNTY IN SANTA CLARITA FROM 0.9 MILE NORTH OF PLACERITA CANYON ROAD UNDERCROSSING TO 0.2 MILE SOUTH OF GOLDEN VALLEY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
| Sample Taken Date | 01/19/2023 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/25/2023 |
| Sample type | Quality Assurance | A brief description of the sample | #8 Gr 80 Bar |
| The quantity of what the sample constitutes | 5251 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 3109128014 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Nucor Skyline | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-001-23 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 80 |
| Threaded Bar Type | Rebar Size | #8 | |
| Nut Specification for Threaded Bar | ASTM A36/ ASME SA-36 | System Manufacturer | Nurcor Skyline |
| Epoxy Coating Color | NA | Threaded Bar Application | Threaded Bar |
| Coating Standards | Uncoated | Bar Heat Number(s) | 3700031281,3700031282,3700035231,3700035232,3 |
| Nut Heat Number(s) | B2615 | Bar Lot Number | |
| Nut Lot Number | 6016 | Coupler Heat Number(s) | |
| Coupler Grade |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2023-01-19-5-1 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-2 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-4 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-5 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-6 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-7 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-8 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-9 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-10 ASTM A615-20 (Verified)
DIME Test ID: 2023-01-19-5-11 ASTM A615-20 (Verified)