Sample Record

DIME Sample ID 2022-12-19-32

Project Information

Project IdentifiersProject ID: 993490
DEA: 051M4604
EFIS: 0519000154
DIST-CO-RTE-PM05-MON-1-44.5
Award Date03/02/2022
Closeout Date06/26/2023
Work DescriptionCONSTRUCT RETAINING WALL, WIDENING SHOULDER AND PLACE HMA. Highway 1 at Coastlands Rd Soldier Pile Wall.
Location DescriptionMONTEREY COUNTY NEAR BIG SUR AT 1.0 MILE SOUTH OF PFEIFFER CANYON BRIDGE
QA Service Level1 (Verified on 01/19/2022)

Owner Lab

  • CT D05 - Monterey Construction Field Laboratory

Sample Information

Sample Taken Date12/19/2022 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing01/20/2023 Sample typeQuality Assurance
A brief description of the sample4" x 8" Cylinders The quantity of what the sample constitutes>300 Cu Yards
From where was the sample collectedJob Site First name of sampler or witnessed byCarson
Last name of sampler or witnessed bySperber Title of samplerASR
Telephone number of sampler Laboratory sample identification1219220800
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Rock Sand City
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number57-2-590R
The truck number from where the sample was collectedNA The batch plant ticket number from where the sample was collectedNA
Concrete batch plantGranite Rock Sand City The fabricator/manufacturer designation for the sampleNA
A detailed description of where the material sample was collectedbelt cut Where the material sample would have been placed if not sampledPile Cap
From Lot No.NA Bag Lot No.NA

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-12-19-32-1CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersWesley Rider, CT D05 - Monterey Construction Field Laboratory01/17/202301/17/2023
Yes
01/17/202329 Day break Due to Holiday.Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-12-19-32-1 CTM 521-June 2020 (Verified)