Sample Record

DIME Sample ID 2022-10-14-24

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215057
DEA: 010F5304
EFIS: 0116000018
DIST-CO-RTE-PM01-HUM-299,200-R1.8,R2.7
Award Date09/02/2020
Closeout Date09/21/2023
Work DescriptionRAISE BRIDGE AND HMA PAVING
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA AT ROUTE 200/299 SEPARATION
QA Service Level1 (Verified on 07/24/2020)

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

Sample Information

Sample Taken Date10/14/2022 Sample Unique Key24
Date that the sample was received by the laboratory/organization performing the testing10/17/2022 Sample typeQuality Assurance
A brief description of the sampleZap Screwlok Type 2 Couplers The quantity of what the sample constitutes150 Couplers
From where was the sample collectedJob Site First name of sampler or witnessed byJarred
Last name of sampler or witnessed byBurrows Title of samplerSR
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameCamblin Steel
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelZap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)MM20104043 Rebar Heat Number(s)2211937
Rebar Size 2 Coupler Unique IDSL-17-03

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-10-14-24-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/202210/18/2022
Yes
10/20/2022service splicePublic - Test Data Visible
2022-10-14-24-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/202210/18/2022
Yes
10/20/2022service splicePublic - Test Data Visible
2022-10-14-24-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)spaine, CT HQ - Sacramento Structural Materials Testing Laboratory10/18/202210/18/2022
Yes
10/20/2022service splicePublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-10-14-24-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-10-14-24-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2022-10-14-24-3 CTM 670-December 2013 (Verified)