Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2022-09-19-14
Project Information
Project Identifiers | Project ID: 993771 DEA: 07325204 EFIS: 0716000082 |
---|---|
DIST-CO-RTE-PM | 07-LA-210-R36.7/R37.1 |
Award Date | 02/15/2022 |
Closeout Date | 01/29/2024 |
Work Description | San Gabriel River Bridge - CM/GC Project - Hinge And Diaphragm Repairs |
Location Description | Los Angeles County - LOS ANGELES COUNTY IN IRWINDALE FROM 0.2 MILE EAST OF 0.7 MILE WEST OF IRWINDALE AVENUE OVECROSSING |
QA Service Level | 1 (Verified on 04/21/2022) |
Sample Information
Sample Taken Date | 09/19/2022 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/21/2022 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders 4x8 |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Vantine |
Title of sampler | ASR | Telephone number of sampler | |
Laboratory sample identification | 1044-3 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | National | Transportation Laboratory (TL) Number | 136458 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | Not Provided |
---|---|---|---|
The truck number from where the sample was collected | Not Provided | The batch plant ticket number from where the sample was collected | Not Provided |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Hinge Replacement Concrete Barrier | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2022-09-19-14-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Jose Guzman, CT D08 - Fontana Southern Regional Laboratory | 09/26/2022 | Jose Guzman | Yes | 09/26/2022 | ||
2022-09-19-14-2 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matthew Clayton, CT D08 - Fontana Southern Regional Laboratory | 10/03/2022 | Matthew Clayton | Yes | 10/04/2022 | ||
2022-09-19-14-3 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matthew Clayton, CT D08 - Fontana Southern Regional Laboratory | 10/10/2022 | Matthew Clayton | No | Info | ||
2022-09-19-14-4 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matthew Clayton, CT D08 - Fontana Southern Regional Laboratory | 10/17/2022 | Matthew Clayton | Yes | 12/13/2022 |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2022-09-19-14-1 ASTM C39-10 (Verified)
DIME Test ID: 2022-09-19-14-2 ASTM C39-10 (Verified)
DIME Test ID: 2022-09-19-14-3 ASTM C39-10
DIME Test ID: 2022-09-19-14-4 ASTM C39-10 (Verified)