Sample Record
DIME Sample ID 2022-09-16-1
Sample is locked from editing. info
Project Information
| Project Identifiers | Project ID: 215255 DEA: 040A7714 EFIS: 0420000287 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80-6.4-6.6 |
| Award Date | 05/03/2021 |
| Closeout Date | 12/01/2023 |
| Work Description | CONSTRUCT PEDESTRIAN OVERCROSSING BRIDGE AND RETAINING WALLS. GILMAN INTERCHANGE IMPROVEMENTS |
| Location Description | ALAMEDA COUNTY IN BERKELEY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.1 MILE SOUTH OF GILMAN STREET UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/07/2020) |
Owner Lab
- CT HQ - QASI Los Angeles Field Office
Sample Information
| Sample Taken Date | 09/16/2022 | Sample Unique Key | 1 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/19/2022 | Sample type | Quality Assurance |
| A brief description of the sample | HRC 150 T-Heads | The quantity of what the sample constitutes | 448 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Arthur |
| Last name of sampler or witnessed by | Peterson | Title of sampler | |
| Telephone number of sampler | 7073428602 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | HRC Fountain Valley | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-103-22 | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Rebar Heat Number(s) | 4121290 | Head Manufacturer Lot Number(s) | Lot no 1 and Lot no 3 |
| Rebar Size | #6 | Headed Bar Model Name | HRC 150 |
| Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
| Head Shape | Circular | Rebar Manufacturer | CMC |
| Head Manufacturer | Nucor Utah Cold Finish Division | Head Fabricator | HRC Fountain Valley |
| Material Standard Code | ASTM A706 | Headed Bar Unique ID | 9FW-17-04 |
Submitted Tests
Sample File Attachments
| File Name | Extension | Date Uploaded | Actions |
|---|---|---|---|
| No results found. | |||
Test File Attachments
DIME Test ID: 2022-09-16-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-09-16-1-2 ASTM A970-18 (Verified)
DIME Test ID: 2022-09-16-1-3 ASTM A970-18 (Verified)
DIME Test ID: 2022-09-16-1-4 ASTM A970-18 (Verified)
DIME Test ID: 2022-09-16-1-5 ASTM A970-18 (Verified)
DIME Test ID: 2022-09-16-1-6 ASTM A970-18 (Verified)