Sample Record

DIME Sample ID 2015-05-06-2

Project Information

Project IdentifiersProject ID: 209681
DEA: 080J9304
EFIS: 0800020192
DIST-CO-RTE-PM08-SBD-15-147.6
Award Date08/25/2014
Closeout Date07/22/2015
Work DescriptionBRIDGE REHABILITATION
Location DescriptionSAN BERNARDINO COUNTY NEAR BAKER AT HALLORAN WASH BRIDGE.
QA Service Level1 (Verified on 10/08/2014)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date05/06/2015 Sample Unique Key2
Date that the sample was received by the laboratory/organization performing the testing05/08/2015 Sample typeQuality Assurance
A brief description of the sample6X12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byAHMAD
Last name of sampler or witnessed byANKIR Title of samplerSTRUCTURE REP
Telephone number of samplerUnknown Laboratory sample identification904-17
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameJOB
Transportation Laboratory (TL) Number081417 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierHALLORAN WASH BRIDGE Structure nameBENT 3 FOOTINGS RT
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSC590B38
The truck number from where the sample was collectedNOT PROVIDED The batch plant ticket number from where the sample was collectedNOT PROVIDED
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2015-05-06-2-2CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete CylindersMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/16/2015
Yes
05/20/2015Public - Test Data Visible
2015-05-06-2-3CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete CylindersMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/20/2015
Yes
05/20/2015Public - Test Data Visible
2015-05-06-2-4CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete CylindersMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/13/2015
Yes
05/13/2015Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-05-06-2-2 CTM 521-November 2014 (Verified)
DIME Test ID: 2015-05-06-2-3 CTM 521-November 2014 (Verified)
DIME Test ID: 2015-05-06-2-4 CTM 521-November 2014 (Verified)