Sample Record

DIME Sample ID 2015-04-15-5

Project Information

Project IdentifiersProject ID: 209019
DEA: 071952U4
EFIS: 0700000201
DIST-CO-RTE-PM07-VEN-23,101-3.3/3.8,R0.1/R4.5
Award Date11/21/2013
Closeout Date06/25/2019
Work DescriptionWIDEN FREEWAY AND RAMPS AND RECONSTRUCT MEDIAN.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS ON ROUTE 101 FROM 0.6 MILE SOUTH OF WESTLAKE BOULEVARD OVERCROSSING TO 0.4 MILE NORTH OF MOORPARK ROAD UNDERCROSSING AND ON ROUTE 23 FROM ROUTE 101 TO 0.1 MILE NORTH OF HILLCREST DRIVE UNDERCROSSING
QA Service Level1 (Verified on 08/13/2013)

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

Sample Information

Sample Taken Date04/15/2015 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing04/21/2015 Sample typeQuality Control
A brief description of the sample6X12 The quantity of what the sample constitutes6
From where was the sample collectedJob Site First name of sampler or witnessed byA
Last name of sampler or witnessed byMAGHSOUDLOO Title of samplerASR
Telephone number of samplerUnknown Laboratory sample identification876-19
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameCollected at jobsite
Transportation Laboratory (TL) Number106619 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierUnknown Structure nameUnknown
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberS72017
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedNOT PROVIDED
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedCHUTE Where the material sample would have been placed if not sampledNot set
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2015-04-15-5-1CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete CylindersMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory04/24/2015
Yes
04/24/2015Public - Test Data Visible
2015-04-15-5-2CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete CylindersMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory05/13/2015
Yes
05/13/2015Public - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-04-15-5-1 CTM 521-November 2014 (Verified)
DIME Test ID: 2015-04-15-5-2 CTM 521-November 2014 (Verified)