Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2022-06-28-23

Project Information

Project IdentifiersProject ID: 215188
DEA: 080F5434
EFIS: 0817000239
Permit Numbers: 0823NMC0369
DIST-CO-RTE-PM08-RIV-I-15,SR-91-6.1-7.6
Award Date03/11/2020
Closeout Date06/05/2024
Work DescriptionI-15 ELC: 15/91 Express Lanes Connector Project (ELC)
Location DescriptionJunction of I-15 and SR-91 in Corona, CA
QA Service Level1 (Verified on 09/16/2020)

Sample Information

Sample Taken Date06/28/2022 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/30/2022
Sample typeQuality Assurance A brief description of the sampleConcrete Cylinders
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byChizitere Last name of sampler or witnessed byOzuruigbo
Title of samplerTET Telephone number of sampler
Laboratory sample identification1026-9 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMeyers Rados JV Transportation Laboratory (TL) Number9
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1614705
The truck number from where the sample was collected10067822 The batch plant ticket number from where the sample was collected52258090
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collected15 91 Temescal WB Bent 13 Columns Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-06-28-23-1ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensJose Mendez, CT D08 - Fontana Southern Regional Laboratory07/26/2022Jose Mendez
Yes
07/26/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-06-28-23-1 ASTM C39-10 (Verified)