Sample Record

DIME Sample ID 2022-05-09-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date05/09/2022 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing05/25/2022 Sample typeQuality Assurance
A brief description of the sample1-3/8" Threaded Bar Grade 150 The quantity of what the sample constitutes7
From where was the sample collectedFabricator First name of sampler or witnessed byLorenzo
Last name of sampler or witnessed byGarcia Title of samplerQuality Assurance Inspector
Telephone number of sampler17029172503 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameWilliams Form
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL115-069-22
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade722
Threaded Bar TypePlain Rebar Size
Nut Specification for Threaded BarA29-Gr. 1045 System ManufacturerWilliam Form
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)100100654
Nut Heat Number(s)75084199 Bar Lot Number10010065420
Nut Lot Number75084199 Coupler Heat Number(s)212448
Coupler GradeA29-Gr. 1045

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-05-09-5-1ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/02/202206/02/2022
Yes
06/06/2022A722 Bar and NutPublic - Test Data Visible
2022-05-09-5-2ASTM A722-18: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/02/202206/02/2022
Yes
06/06/2022A722 Bar, Nut, CouplerPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-09-5-1 ASTM A722-18 (Verified)
DIME Test ID: 2022-05-09-5-2 ASTM A722-18 (Verified)