Sample Record

DIME Sample ID 2022-05-03-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

Sample Information

Sample Taken Date05/03/2022 Sample Unique Key1
Date that the sample was received by the laboratory/organization performing the testing05/04/2022 Sample typeQuality Assurance
A brief description of the sample#10 bar HRC 120 T-head The quantity of what the sample constitutes30 Headed Bars
From where was the sample collectedFabricator First name of sampler or witnessed byOsiel
Last name of sampler or witnessed byRamirez Title of sampler
Telephone number of sampler5599740870 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameHeaded Reinforcement Corp, Fountain Valley, CA
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL123-037-22
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4114788 Head Manufacturer Lot Number(s)100021479644
Rebar Size#10 Headed Bar Model NameHRC 120 T head
Size of HeadFull Size - 9x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Steel Arizona
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedDate AddedVerified?Release DateTest CommentsPrivacy LevelActions
2022-05-03-1-1ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/202205/11/2022
Yes
05/11/2022Ok NeckingPublic - Test Data Visible
2022-05-03-1-2ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/202205/11/2022
Yes
05/11/2022Ok NeckingPublic - Test Data Visible
2022-05-03-1-3ASTM A970-18: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)bewing, CT HQ - Sacramento Structural Materials Testing Laboratory05/11/202205/11/2022
Yes
05/11/2022Ok NeckingPublic - Test Data Visible

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-05-03-1-1 ASTM A970-18 (Verified)
DIME Test ID: 2022-05-03-1-2 ASTM A970-18 (Verified)
DIME Test ID: 2022-05-03-1-3 ASTM A970-18 (Verified)